Please use this identifier to cite or link to this item: http://repositorio.uisek.edu.ec/handle/123456789/3888
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMartínez-Gómez, Javier-
dc.contributor.authorBustamante-Crespo, Mario F.-
dc.contributor.authorSalazar, Paolo-
dc.contributor.authorLobato Cordero, Andrea-
dc.contributor.authorNarváez C., Ricardo-
dc.contributor.authorMacías, José-
dc.contributor.authorCordovéz-Dammer, Martín-
dc.date.accessioned2020-08-18T16:10:12Z-
dc.date.available2020-08-18T16:10:12Z-
dc.date.issued2019-07-17-
dc.identifier.citationPUB M386ca/2019es
dc.identifier.issn2602-8492-
dc.identifier.issn1390-5074-
dc.identifier.urihttps://repositorio.uisek.edu.ec/handle/123456789/3888-
dc.descriptionEn esta investigación tiene por objeto mejorar las condiciones de habitabilidad y consumo de energía en edificaciones. Promoviendo nuevos reglamentos y políticas que impulsen la construcción garantizando confort térmico y el diseño mecánico en el sector de la construcción. Para ello, se evaluaron los ensayos térmicos y mecánicos del roble, de la región Costa (Manabí y El Oro) y Sierra (Loja) de Ecuador. En este estudio se realizó la caracterización térmica mediante conductividad térmica, contenido de humedad y caracterización mecánica, mediante ensayos de resistencia a la tracción, a la flexión, a la compresión paralela y perpendicular a la fibra de la madera, aplicando normas Internacionales y Nacionales. Los resultados del ensayo térmico de las probetas de la madera dura roble muestran que en el 88.9 % probetas la conductividad térmica se encuentra en el rango de 0,16 y 0,19 (W/m K). Estos valores se corresponden con la norma ASTM-C177.es
dc.description.abstractThe purpose of this research is to improve building living conditions and energy consumption, promoting new regulations and policies that promote construction, guaranteeing thermal comfort and mechanical design in buildings. For this, the thermal and mechanical tests of the oak, from the Costa region (Manabí and El Oro) and Sierra (Loja), from Ecuador, were evaluated. In this study, characterization was carried out using thermal conductivity, moisture content tests, and tensile, flexural, parallel and perpendicular compression tests, applying International and National standards. The results of the thermal test of the samples of the oak hardwood show that in 88.9 % of specimens the thermal conductivity has to be between the range of 0.16 and 0,19 (W/m K). These values correspond to the ASTM-C177 standard.es
dc.description.sponsorshipUisekes
dc.language.isospaes
dc.publisherRevista Técnica Energíaes
dc.rightsopenAccesses
dc.subjectCONFORT TÉRMICOes
dc.subjectMADERAes
dc.subjectROBLEes
dc.subjectCONSTRUCCIÓNes
dc.subjectEDIFICACIONES.es
dc.titleCaracterización térmica y mecánica de la madera de roblees
dc.title.alternativeThermal and mechanical characterization of oak woodes
dc.typeinfo:eu-repo/semantics/articlees
Appears in Collections:Publicaciones UISEK

Files in This Item:
File Description SizeFormat 
13905074 MARTINEZ JAVIER 2019-07-31.pdf346.73 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.